T214 main unit installation
Chapter 4. Installation.
35
The table below details I/O connector’s pin assignment:
Description of pins
Connector
type
Name of
connector
Number Designation Interface type
1 DCD
2 Rx
3 Tx
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
MAIN,
AUX
9 Not
used
2 Rx
3 Tx
5 GND
Display
1,4,6-9 Not
used
RS232C
1 Rx+
2 Rx-
5 GND
SENSOR
3,4,6-9 Not
used
RS422
3 Rx/Rx-
5 GND/Rx+
DB9-female
RTCM
1,2,4,6-9 Not used
RS232/RS422
The table below details the description of Ethernet, Digital I/O, 1PPS connectors:
Description of pins
Connector type
Connector
name
Number
Designation
Interface type
1 T
2 Transmit-
3
6 Receive-
9,10 Shield
Ethernet
4,5,7,8 Not
used
Ethernet 10 Base
T
1 +24VDC
2 D/O
#1
3 D/O
#2
4 D/O
#3
5 D/I
#1
6 D/I
#2
7 D/I
#3
8 GND
RJ45-female
Digital I/O
9,10 Shield
Inputs D/I #x:
“1” — 5÷30 V
R
in
≥
5.6
кΩ
Outputs D/O #x:
Type
–
open
drain,
U
max
= 50 V
I
max
= 150 mA,
r
DS(on)
= 9.5
Ω
1 1PPS
BNC-female 1PPS
Case GND
Pulse +2.4÷5
В
,
τ
>1 ms, R=50
Ω
Summary of Contents for T214
Page 1: ... Transas Ltd April 2007 TRANSAS AIS BASE STATION T214 TECHNICAL MANUAL ...
Page 6: ......
Page 8: ......
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 30: ......
Page 40: ......
Page 42: ......
Page 48: ......
Page 52: ...Service Display program TRANSAS AIS BASE STATION T214 Technical Manual 50 ...
Page 84: ......
Page 100: ......
Page 102: ......
Page 108: ......
Page 110: ......