Trunks
300 Trunk Assignment
6-10
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
F
IELD
D
ESCRIPTION
Line No.
Enter the trunk equipment number.
Possible values: xx = Cabinet 01~07; yy = Slot 01~10; zz = Circuit 01~08 or
zz=T1 Circuit 01~24 (CTX670)
xx = Cabinet 01; yy = Slot 01~08; zz = Circuit 01~24 (CTX100)
(default = no value)
Note
Equipment numbers are required when assigning a new trunk to the
system. It can also be used to display the equipment location of existing
trunks.
01 Auto Release
Select the Automatic Release timing.
Possible values: Disable, Detect 95ms or Detect 450ms (default)
Note
Select Disable if the CO does not send the automatic release signal to the
loop start trunk.
02 Short Flash
Select Short Flash Time
Possible values: 0~15, where 1 = 100msec. (default = 5, which is .5 seconds)
0 = no flash, 1 = .1 sec., 2 = .2 sec. – 15=1.5 sec. 5 is the most
common duration of a hook flash signal
When a telephone initiates the short flash signal to the CO line it is connected to
(using the short Flash feature button or access code #450) the duration of a short
flash is determined by this command. Normally this signal is used to hook flash a
centrex line. The short flash range is 0 to 1.5 seconds in increments of 0.1 seconds.
03 Long Flash
Select Long Flash Time.
Possible values: 0, 5, 10, 15, 20, 25 and 30, where 5 = .5 seconds. (default = 5)
When a telephone initiates the long flash signal to the CO line it is connected to
(using the Long Flash feature button or access code #451) the duration of a long
flash is determined by this command. Normally this signal is used to disconnect the
line. The long flash range is 0 to 3 seconds in increments of 0.5 seconds. Possible
values: 0=no flash, 5=.5 sec., 10=1sec. 15=1.5 sec., 20=2 sec., 25=2.5 sec., 30=3
sec.
04 Pause after Flash
Pause time after flash: After a flash signal is sent to a CO line, this timer determines
when the line will start to send the dialed digits to the other end.
Possible values: 0~5, 0 = immediately sent, and 1sec.delay to 5sec.delay
(default = 1 second delay before sending digits)
05 Response
Information
The response timer is for analog DID/TIE lines that have the “start method” set for
“Timing” in Prg300-06. After a line is seized this timer determines when the line will
start to send the dialed digits to the other end.
Possible values: 0=immediatly sent, and 50msec.delay to 500msec.delay
(default = 500mseconds delay before sending digits)
Summary of Contents for Strata CTX
Page 14: ...Contents Appendix E Software and Firmware Updates x Strata CTX Programming 04 03 ...
Page 20: ......
Page 36: ......
Page 278: ......
Page 396: ......
Page 516: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 04 03 ...