Telephone Button Programming
Button Programming Examples
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
13-5
T
e
lep
hone
Button
Pr
o
g
ram
m
ing
Button Programming Examples
The following examples show you how to use the Strata CTX button programming interface. Toshiba
highly recommends the use of Strata CTX WinAdmin to meet the demands of your telephone system
programming.
Suppose a customer needed to assign a DKT Station to a PDN. Based on the
“Identify Program
Sequences”
on
page 1-11
, you can immediately identify the Program numbers and sequence required to
complete this basic task. Login to the Button Programming Mode using the directions on
page 13-7
and
follow the steps below.
Program 100
Reference
“Program 100”
on
page 13-11
. For this example, an eight station BDKU PCB is assigned to
Slot 01/Cabinet 01 (xxyy).
1. Enter programming mode. See “
Step 1: Enter Program Mode
on
page 13-7
."
2. At the
PROG=
prompt enter
and press
+ROG
.
3. At the
EQUIP=
prompt enter
(xxyy) and press
+ROG
.
“Program 100”
on
page 13-11
tells us that a three digit PCB code (nnn) is required. From the table,
“PCB Codes”
on
page 13-12
, we can derive that the PCB code for a BDKU is “017.” Furthermore, the
“Program 100” table shows us the button sequence required for programming a BDKU in the fourth
row of the table.
4. Press
)%
. Enter
and press
+ROG
.
“Program 100”
on
page 13-11
also informs us that an “n” value is required to complete the PCB
assignment. These “n” values are listed in the column titled “Value(s).” When you look in the fourth
row of the “Value(s)” column there are five “n” value choices. For this example, select “2. 8 DKT no
OCA.”
5. Press
)%
. Enter
and press
+ROG
twice.
6. Press
+ROG
to return to the
PROG=
prompt.
Program 200
Reference
“200 Series Programs”
on
page 13-27
. A DKT assignment (DN = 1000) is made to Circuit 01,
Slot 01, and Cabinet 01 for the BDKU card installed in Step 1 above.
1. Enter programming mode. See “
Step 1: Enter Program Mode
on
page 13-7
."
2. At the
PROG=
prompt enter
and press
+ROG
.
3. At the
DN=
prompt enter
(n) and press
+ROG
.
4. Press
)%
. At the
EQUIP=
prompt enter
(xxyyzz) and press
+ROG
.
5. Press
)%
. Press
to select a DKT and press
+ROG
.
6. Press
)%
. Press
to select Extension as the Circuit Type and press
+ROG
.
For this example, only the above
)%
s need to be assigned. Press
+ROG
again before proceeding to the
next step.
7. Press
+ROG
to return to the
PROG=
prompt.
Note
Additional assignments can be made to fine tune this DKT assignment. If specific assignments are
not made, the system automatically assigns the default value.