Telephone Button Programming
300 Series Programs
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
13-69
T
e
lep
hone
Button
Pr
o
g
ram
m
ing
323
CBC Service
,
+ROG
To accomplish CBC services, each facility needs to be defined, its
related Line Group assigned and minimum and maximum values for
the services provided. These service parameters may be set for three
different time zones, thus allowing fewer or more services of different
types at different times of the day.
323-00
Channel Group
n,
+ROG
n =
1~32 (CTX100)
1~48 (CTX670 Basic)
1~128 (CTX670 Exp.)
Enter the Channel Group Number.
323-01
Index
)%
, n,
+ROG
n =
0~32 (CTX100)
0~48 (CTX670 Basic)
0~128 (CTX670 Exp.)
Enter the CBC Service Index, or click one of the following buttons:
•
List – view a summary list of programmed Trunks.
•
Create – Assign a new Trunk with default settings.
323-02
Type of Service
)%
, n,
+ROG
n =
1.
No Data (default)
2.
POTS
3.
FX
4.
Tie line (Enbloc)
5.
Tie line (Cut throuogh)
6.
Intra LATA Out WATS
7.
Banded Out WATS
8.
Inter LATA Out WATS
9.
INWATS
Select the CBC Service Type.
Note
To delete CBC, set this field to
1: No Data
.
323-03
Facility Code
)%
, n,
+ROG
n =
00~31
Enter the supplied Facility code value from the PSTN. If no data is
entered in this field, any previously entered data is deleted.
323-04
Service Parameter
)%
, n,
+ROG
n =
Up to 5 digits
Enter the Service parameters supplied from PSTN. If no data is
entered in this field, any previously entered data is deleted.
323-05
Network ID
)%
, n,
+ROG
n =
3~4 digits
Enter the Network ID code supplied from PSTN (this field is required if
you selected “Inter LATA Out WATS” Type of Service. If no data is
entered in this field, any previously entered data is deleted.
323-06
ILG
)%
, n,
+ROG
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
Specify the ILG for this facility.
323-07
OLG
)%
, n,
+ROG
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
Specify the OLG for this facility.
323-08
Min Calls Zone 1
)%
, n,
+ROG
n =
0~47
(default = 0)
Select the minimum number of Bch in Time Zone 1.
323-09
Max Calls Zone 1
)%
, n,
+ROG
n =
0~47
(default = 47)
Select the maximum number of Bch in Time Zone 1.
323-10
Min Calls Zone 2
)%
, n,
+ROG
n =
0~47
(default = 0)
Select the minimum number of Bch in Time Zone 2.
323-11
Max Calls Zone 2
)%
, n,
+ROG
n =
0~47
(default = 0)
Select the maximum number of Bch in Time Zone 2.
323-12
Min Calls Zone 3
)%
, n,
+ROG
n =
0~47
(default = 0)
Select the minimum number of Bch in Time Zone 3.
323-13
Max Calls Zone 3
)%
, n,
+ROG
,
+ROG
n =
0~47
(default = 0)
Select the maximum number of Bch in Time Zone 3.
Programs 321~324
(continued)
Button