![background image](http://html.mh-extra.com/html/toshiba/strata-ctx/strata-ctx_programming-manual_428810256.webp)
Operation
911 Remote Program Update
10-12
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
Important!
●
If power is turned off/on or if the Strata CTX is re-started before switching the Active software from
“Trial” to “Normal”, the CTX670 will switch the old software back to Active.
●
It is your responsibility to verify the system is working correctly after Remote Update is complete.
Notes
●
If the new version of software is not performing properly, on the CTX670 only, you can activate
the old version of software again by initiating a Clear-reboot.
●
Clear-reboot swaps the active and standby sides of flash memory. You must always install a
SmartMedia card containing a copy of the current back up data before initiating a Clear-reboot or
all programmed data will be erased.
●
If the CTX100 system is not working properly with the new software, you must reinstall the
original software using this Update procedure.
Table 10
Program Update Screen Field Descriptions
F
IELD
D
ESCRIPTION
Upload from Folder
Select the Strata CTX type.
Possible values: CTX100_R_MXnnn, CTX670_R_MXnnn.
Version Number
Software version number displays. Example: A102MXnnn00. See
CTX Software
Identification
.
Number of Files
Displays number of files that have to be uploaded. This file is static.
Files Uploaded
Displays number of files uploaded. This is a dynamic field and will change during
the process.
Operation
Completion
View operation status.
Copied blocks
View number of blocks copied.
Possible values: 0~65536 (default = 0)
Total Blocks
View total blocks to be updated.
Possible values: 0~65536 (default = 0)
Active Side ID
Active Side Number.
Possible values: 0 or 1 (default = 0)
Active Side Status
Software status display.
Possible values: Normal (default), Trial, Fault, Don’t care or Error
Standby Side Status
Standby Backup Type. This field will display only when connected to a CTX670. It
will not display when connected to CTX100.
Possible values: Normal (default), Trial, Fault, Don’t Care or Error