System Error Codes
Trunk Programming Error Codes
Strata CTX Programming - Part 4: Appendices 04/03
B-15
Sy
s
te
m
Error Code
s
320
33
)%
The entered equipment value is invalid.
54
)%a)%
The quantity of lines, ISDN channels and PDNs entered
exceeds the number of ports licensed with this processor.
80
)%
The circuit for the designated PCB must be an assigned ISDN
primary trunk.
321
80
)%
The entered OLG number does not exist in the system.
322
33
The Group CO or Pool Line Group Destination is out of range
(1~128).
80
)%
The entered OLG number does not exist in the system.
80
)%
)%
The designated extension number does not exist in the
system.
80
)%
)%
The entered GCO value does not exist in the system.
80
)%
)%
The entered POOL value does not exist in the system.
96
)%
The allowable system DID assignments has been exceeded.
323
18
)%
Select the Type of Service for CBC.
33
)%
The Incoming Line Group entered is invalid.
33
)%
The Outgoing Line Group entered is invalid.
49
)%a)%
The same value is designated to the Type of Service, Facility
Code, Service Parameters, and Network ID fields that
correspond to the same channel group and different line
service index.
49
)%
The entered values in Channel Group and Index fields are not
valid CBC assignments. Select NODATA in Type of Service
field to delete CBC setting.
49
)%
)%
When an INWATS ILG is assigned in ILG field an Out WATS
Type of Service cannot be assigned.
49
)%
)%
If OUTWATS service is selected for Type of Service, an OLG
value must be assigned.
49
)%
)%
The selected ILG conflicts with an existing ILG number.
49
)%
)%
When an Out WATS OLG is assigned in OLG field an INWATS
Type of Service cannot be assigned.
49
)%
)%
Make a selection in OLG field.
49
)%
)%
The selected OLG conflicts with an existing ILG number.
49
)%a)%
The assigned minimum Bch value (Minimum Calls Zones
1~3) exceeds the related (Maximum Calls Zones 1~3)
maximum Bch value.
49
)%
)%
)%
The assigned minimum Bch value (Minimum Calls Zones
1~3) exceeds the related (Maximum Calls Zones 1~3)
maximum Bch value.
Program
Code
Occurred
FB
Sub-
parameter
Error Descriptions
Summary of Contents for Strata CTX
Page 14: ...Contents Appendix E Software and Firmware Updates x Strata CTX Programming 04 03 ...
Page 20: ......
Page 36: ......
Page 278: ......
Page 396: ......
Page 516: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 04 03 ...