System Error Codes
Service Programming Error Codes
Strata CTX Programming - Part 4: Appendices 04/03
B-17
Sy
s
te
m
Error Code
s
Service Programming Error Codes
Program
Code
Occurred FB
Sub-
parameter
Error Descriptions
500
32
)%
)%
A character that is not permitted is included in the Destination
number.
50
)%
A value must be assigned to Destination 1if an assignment
was made in Destination 2.
82
)%
The entered System Call Forward number does not exist in
the system.
501
32
)%
A character that is not permitted is included in the entered
Speed Dial number.
33
)%
The entered Speed Dial number is out of range.
502
51
)%
The entered DN does not exist in the system (the entered
value conflicts with an existing extension number or
numbering plan).
52
)%
The entered number conflicts with an existing numbering plan.
80
)%
The entered extension does not exist. The entered Attendant
Console does not exist.
96
-
The Page group number entered exceeds the system’s
capacity.
98
)%a)%
The number of allowable Device number per paging group
has been exceeded.
503
49
)%
The entered External Generic Relay number conflicts with an
existing device, such as a door lock, etc.
96
The Page group number entered exceeds the system’s
capacity.
98
)%a)%
Device Number per paging group is exceeded.
504
-
No error occurs for this Program except for common errors.
506
53
)%
Account Code cannot be verified.
80
)%
Account code confirmation digit does not coincide. (It is larger
than the value that was registered by Program 570.)
98
)%
The Account code number exceeds the system’s capacity.
Summary of Contents for Strata CTX