Services
Networking
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
9-35
Serv
ice
s
Network DSS (R1.3 and higher)
When you set up Network DSS, you assign the DSS numbers in the local CTX first. Then, once you
network the remote CTXs, they will use the DSS numbers set in the local CTX. Prior to R1.3, DSS
numbers had to be assigned to each remote CTX.
An example of how to set up Network DSS is shown in
Figure 9-4
. In this example, if CTX670-1 is the
local/host site, then CTX670-2 and CTX100 become remote sites.
Figure 9-4
Network DSS Example
Use the following steps to program Network DSS from WinAdmin:
1. Create the Node ID in
“102 Flexible Access Codes”
on
page 4-3
.
Note
If you have already created the Node ID using QSIG, skip Step 1 and go to the next step.
2. Use Program
“916 IP Configuration” on page 10-14
to set up the IP address for each CTX.
3. Program the CTI Port for Network DSS. From the Program menu, select System > I/O Device. Refer to
“803 SMDR SMDI CTI Port Assignments”
on
page 4-27
.
•
00 Logical Device No. = 500 (DSS)
•
01 Device Connection = LAN
•
02 Device Port No. = 12
6591
Example Procedure to Assign Network DSS in Node 16
1. Program 916 assigns IP Addresses.
2. Program 803 assigns Network DSS Port (Port 12).
3. Program 801 assigns DSS Server Port 3000.
4. Program 651~656 and 102 assign Strata Net Node IDs and network (QSIG).
5. Program 670 assigns Remote Nodes (17, 18) and their DSS Server Ports.
6. Program 205 or 215 assigns Network DSS keys on stations.
7. Repeat steps 1~6 for nodes 17 and 18. Note: Steps 4 and 5 assign parameters for remote nodes only
.
Remote
(CTX100)
Program 916 - Set
IP Address =
192.168.1.44
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
=
3000
Program 670 - 00 LAN
Port =
12
Program 916 - Set IP
Address =
192.168.1.43
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
=
3000
Program 670 - 00 LAN
Port =
12
Program 916 - Set IP
Address =
192.168.1.53
Program 803 - Log. Device
= 500 (DSS), Port 12
Progra 801 - DSS Port
=
3000
Program 670 - 00 LAN
Port =
12
QSIG
QSIG
Local
(CTX670-1)
Remote
(CTX670-2)
LAN / Switch / Hub
LAN / Switch / Hub
LAN / Switch / Hub
IP-Network
IP-Network
Strata Net
Node ID: 16
Program 670
Remote Node ID: 17
Program 670
Remote Node ID: 18
Summary of Contents for Strata CTX
Page 14: ...Contents Appendix E Software and Firmware Updates x Strata CTX Programming 04 03 ...
Page 20: ......
Page 36: ......
Page 278: ......
Page 396: ......
Page 516: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 04 03 ...