Trunks
300 Trunk Assignment
6-12
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
01 Day1 Destination Type
02 Day2 Destination Type
03 Night Destination Type
Select Destination Type for each.
Possible values: : No Data (default), Dialing Digits, DISA, Built-in Modem, or
Night Bell
•
No Data – no destination will ring when the line rings into the system.
•
Dialing Digits – assigns the line to ring the directory number or access
code defined in the “Destination Digits” assignment
•
DSIA – assigns the line to ring in as a DSIA call. DSIA dial tone will be
returned to the caller.
•
Modem – assigns the line to ring the remote maintenance modem on the
CTX processor. Used to call into the system with a CTX WinAdmin PC and
modem.
•
Night Bell – Assigns the line to cause the night relay to pulse (one-
sec.close/3-sec.open)
Day1 Destination Digits
Day2 Destination Digits
Night Destination Digits
Enter Destination, Directory Number or Access Codes for each, only if Dialing
Digits is selected as Destination Type.
•
If Dialing Digits is the Destination Type, enter the Directory Number that the
line should ring.If the line should ring over external page, enter #31xx,
where xx is the external Page group number.
•
If the default page access code #31 was changed, use the new page
access code as the leading digits.
•
Line access codes and network routing numbers can also be entered to
route incoming calls back out to a public or private network number.
Possible values: Up to 32 digits (default = no value)
04 MOH Source
Select the MOH source for Analog DIT Trunk. The Scroll key must be used to
select MOH sources indicated by 10 or higher.
Possible values: External1~15 (default = External1)