![background image](http://html.mh-extra.com/html/toshiba/strata-ctx/strata-ctx_programming-manual_428810351.webp)
Telephone Button Programming
500 Series Programs
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
13-73
T
e
lep
hone
Button
Pr
o
g
ram
m
ing
502-17
All Page Group
)%
, n,
+ROG
n =
1.
On
2.
Off (default)
Enter this station in all Paging Groups.
502-18
All Emergency Page
Group
)%
, n,
+ROG
,
+ROG
n =
1.
On
2.
Off (default)
Enter this station in all Emergency Paging Groups.
503
Paging Devices
Group Assignment
,
+ROG
Assigns BIOU Page Zone Relays to Page Groups.
503-00
Zone Relay Number
n,
+ROG
n =
1~8
•
BIOU1 = 1~4
•
BIOU2 = 5~8
Select the BIOU Page Zone relay that should be assigned to the Page
Groups below. This relay activates whenever the selected Page
Group is paged.
•
BIOU1 = Zone Relays 1~4.
•
BIOU2 = Zone Relays 5~8.
503-
01~16
PG01~PG16
)%
~
)%
, n,
+ROG
n =
1.
On
2.
Off (default)
Turn on if the selected BIOU Page Zone Relay should activate with
this Page Group.
503-17
All Page Group
)%
, n,
+ROG
n =
1.
On
2.
Off (default)
503-18
All Emergency Page
Group
)%
, n,
+ROG
n =
1.
On
2.
Off (default)
503-19
BGM Mute Relay
)%
, n,
+ROG
,
+ROG
n =
0~8 (default = 0)
•
BIOU1 = 1~4
•
BIOU2 = 5~8
Assign BIOU generic relay as the BGM mute relay. This relay
activates whenever the external page is in use
•
BIOU1 = Generic Relays 1~4.
•
BIOU2 = Generic Relays 5~8.
Note
The CTX100 ACTU built-in relay is programmed as relay 5.
For this relay operation,BIOU2 is installed, as default, in a
virtual equipment position - Cabinet 2, Slot 5, PCB code 20,
in Program 100. To install an actual BIOU2 and disable the
ACTU built-in relay, use the programming telephone to
remove the virtual BIOU2 and then install the actual BIOU2 in
Cabinet 01 Slot 01~08 in the normal manner.
504
System Call Forward
Operation Status
,
+ROG
This command assigns System Call Forward Type for the pattern.
504-00
SCF Number
n,
+ROG
n =
1~4 (CTX100)
1~10 (CTX670 Basic)
1~32 (CTX670 Exp.)
Select the SCF pattern number to configure.
504-01
Telephone Status
)%
, n,
+ROG
,
+ROG
n =
1.
No Data (default)
2.
Busy
3.
No Ans
4.
Busy No Ans
5.
DND
Select the status or state in which the telephone should be for this
system call forward pattern to activate.
Notes
•
Each 500-01 call type must be the same telephone status. Also,
all calls must be the same Call Forward type.
•
Telephone status must be the same as telephone status selected
in 500-03.
506
Verified Account
Codes
,
+ROG
This program adds or deletes entries in the DR Table associated with
the DRL.
506-00
Account Code
n,
+ROG
n =
Up to 15 digits
Enter a valid accounting code that the user will be expected to dial.
Digits 0~9 can be used.
Note
The Account Code is set to the same digit length as the
Verified Digit Length in Program 570 above.
Programs 500~577
(continued)
Button
Sequence
Value(s)