Software and Firmware Updates
IP Telephone/BIPU Firmware Update Procedures
E-6
Strata CTX Programming - Part 4: Appendices 04/03
10. After the update is complete, select IP Telephone > BIPU Configuration. Check the BIUP version
numbers to verify they have been updated properly.
11. Select Maintenance > Components > Cabinet. Enable the BIPU cabinet slot. This will also cause all IP
telephones that are connected to the disabled BIPU to be in the operational mode.
IP Telephone Update
Important!
Complete all
“Prerequisites”
on
page E-4
before you do the following.
➤
Copy the DIPXXXX file into the WinAdmin PC CTXIPUPDATE directory.
Notes
•
The directory location should be C:\Ctx\W inAdmin\CTXIPUPDATE The drive letter must be the
drive on which WinAdmin is installed.
•
(XXXX in the DIP file name is the firmware version level of the IP telephone).
➤
From the WinAdmin PC perform the update
1. Select Maintenance > Components > Cabinet.
2. Force Disable the BIPU cabinet slot. This will also cause all IP telephones that are connected to the
disabled BIPU to be in the “MAKE BUSY” mode.
3. Select IP Telephone > IPT Program Update.
4. Select the IPT PDN to be updated.
5. Select Local WinAdmin (radio button).
6. Enter the ftp user login Name and Password.
Note
If in doubt, create a new Window logon User Name and password and use it in Step 6.
7. The IP address of the WinAdmin PC is inserted automatically.
8. From Data Directory box enter: CTXIPUPDATE
9. From File Name box enter: DIPUXXX
10. Click Start and observe the update status: Getting Updated file\Updating\Finished
Updating\Resetting\idle.
Notes
•
It could take 30 seconds to 2 minutes to update the IP telephone
•
If an error occurs, recheck file names, locations etc. and try again.
11. Select Maintenance > Components > Cabinet. Enable the BIPU cabinet slot that supports updated IP
telephones. All IP telephones connected to this BIPU should be idle and functioning.
12. Select IP telephone > Station Data. Check the IPT version number to verify that all IPTs have been
updated properly.
13. To check the IP telephone firmware version directly from an IP telephone.
•
Simultaneously press the
+ROG
buttons on the IP Telephone.
•
At the SELECT = prompt, press
then press
+ROG
.
•
At the Select function key prompt, press
)%
, the IP telephone will be displayed.
•
To exit this mode, go off and on hook.
Notes
•
The WinAdmin PC cannot be connected directly to the CTX processor network jack.
•
All connections must be through the network.