Telephone Button Programming
Telephone Button Overview
13-4
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Programming Sub-parameters
Some commands enable programming of Sub-parameters to further refine Strata CTX settings. Internet or
Network IP addresses are entered using sub-parameter data. IP addresses are displayed as four three-digit
values, or Octets, separated by “periods” (e.g., 192.168.255.253). Your programming telephone’s LCD is
only capable of displaying the IP information three digits, or one Octet, at a time.
For example, selecting
)%
in Program 916 displays the first Octet, 192, on the LCD. To view or change
the next Octet (in this example 168) in the IP Address, press the
6SNU
button. Pressing
6SNU
again,
displays the following Octet (in this example 255).
The following is an example from Program 200,
)%
.
)%
is broken down into three sub-parameters as
follows COS DAY1, COS DAY2 and COS NIGHT.
1. At the
SELECT PARAM
prompt, press
)%
.
2. At the
COS DAY1=
prompt, enter a value from 1~32.
3. Press
6SNU
.
4. At the
COS DAY2=
prompt, enter a value from 1~32.
5. Press
6SNU
.
6. At the
COS NIGHT=
prompt, enter a value from 1~32.
7. Press
+ROG
to submit.
8. Press another
button to program more parameters
...or press
+ROG
again to program a new DN.
Note
To change one of the sub-parameters, you must proceed through all three sub-parameters before
pressing
+ROG
. For example, to change the value of COS DAY1, you must change the COS DAY1
value, then press
6SNU
twice, and finally, press
+ROG
.