System
105 System Data
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
4-13
Sy
stem
08 E911 Service
Enable E911 Service availability.
Possible values: Enable (default) or Disable
09 DR Override by SSD
Enable DR Override by System Speed Dial.
Possible values: Enable (default) or Disable
10 Auto Station Release
Enable Automatic Station Release.
Possible values: Enable (default) or Disable
11 ISDN SPID
Enable Auto Service Profile Identifier (SPID).
Possible values: Operable or Not Operable (default)
12 Night Mode Relay
Assign BIOU Relay as the Night Relay. This relay activates when the system is
in the Night Mode.
Possible values: 0~8 (default = 0)
BIUO1 provides relays 1 to 4; BIUO2 provides relays 5 to 8
Note
On CTX100 the ACTU built-in relay is programmed as relay 5. For this
operation, in Program 100 the BIOU2 must be installed in Cabinet 2,
Slot 5, PCB code 20.
13 BGM External Paging
Set the External Page Group Number that includes the external paging zones
to which BGM will be sent. See Program 503
Possible values: 0~4 (CTX100)
0~8 (CTX670 Basic)
0~16 (CTX670 Expanded) (default = 0)
14 Lost Call Destination
Enter Lost Call Destination. If no value is entered in this field any previously
programmed data is lost.
Possible values: Up to 5 digits (default = no value)
15 COS Override Code
Select Class of Service Override Code.
Possible values: 1~8 (default = 1)
16 Multi-Conference
Enable Multi-Conference capabilities for Analog Internal Calls and Outgoing
Calls.
Possible values: Enable or Disable (default)
17 Caller Number Display
Enable Caller Number Display. If a soft key display competes with a Caller ID,
the Caller ID displays.
Possible values: Enable (default) or Disable
18 Night Bell Relay
Assign BIOU Relay as the Night Bell Relay; this relay activates whenever Night
Ringing takes place.
Possible values: 0~8 (default = 0)
BIUO1 provides relays 1 to 4; BIUO2 provides relays 5 to 8
Note
On CTX100 the ACTU built-in relay is programmed as relay 5. For this
operation, in Program 100 the BIOU2 must be installed in Cabinet 2
Slot 5, PCB code 20.
19 Display Preference
Select Display Preference.
Possible values: DNIS (default) or Caller ID