Telephone Button Programming
900 Series Programs
13-98
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
1. Press
)%
to enable Start or Stop trace. Use the number key pad to make your selection.
2. Press
+ROG
.
Notes
●
Start indicates the trace was previously started and is currently running.
●
Stop indicates the trace is not running and all trace buffer data was transferred to SmartMedia.
3. Press
)%
to enter trace file size. To change the setting, use the number Dial Pad.
4. Press
+ROG
.
5. Press
)%
to set trace category. To view setting options, press the
6FUROO
or
3DJH
button.
6. Press
+ROG
twice to execute. Wait for the
PROG
=
prompt to display before proceeding.
7. Enter another program number to continue programming or press
+ROG
again to exit programming
mode.
Note
When CTX 670 stops logging data, it automatically sends data to the SmartMedia card. A new trace
file is stored on SmartMedia under the Evnttrace directory. Run the Unmount command (Program
908) before removing the SmartMedia card to ensure complete data transfer.
FB Name
FB
Summary
Value
LCD Prompt
Trace State
01
Enter
or
to Start or Stop Message
Trace. Stopping the trace outputs data to
the SmartMedia card. Wait for the
352*
prompt on the LCD before proceeding.
Before removing the SmartMedia card run
Program 908. See
“Format/Unmount
SmartMedia”
on
page 13-101
.
1:Start
2:Stop
1:START
2:STOP
Trace Size
02
Set the trace data size. Toshiba
recommends leaving this parameter at the
default setting which provides
approximately 15 minutes of trace data.
1~256 (in bytes)
1 unit = 16 bytes.
default = 2
SIZE=
Trace Category
03
Trace data type to be stored.
1:Call Processing
2:Maint and Admin
3:Both of the above
1.CP
2.M&A
3.CP+M&A (default)