Trunks
300 Trunk Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
6-9
T
runk
s
308 Trunk Timer
Prerequisite Program:
300
on page 6-6
These commands assign Trunk timers.
1. Complete the
“Trunk Timer/DIT
Record Sheet”
on
page D-27
.
2. From the Program Menu, click
Trunk > Assignment, then click the
Timer tab. The Trunk Timer and
DIT Assignments screen displays
(shown right).
3. Enter Trunk equipment number
field. Enter Program 308 data.
•
List – to view a summary list of
programmed Trunks timers.
•
Copy – to copy to trunk timer
ports.
4. Click Submit.
F
IELD
D
ESCRIPTION
Trunk Number
Enter the Trunk Number.
Possible values: 1~64 (CTX100), 1~96 (CTX670 Basic),
1~264 (CTX670 Exp.), (default = no value)
01 Signaling Method
Specify the format for the interface being used.
Possible values: Nothing (default), ANI/DNIS-MCI, ANI/DNIS-Sprint or
CLASS (Caller ID)
02 Signaling Contents
Specify the contents of the ANI/DNIS format.
Possible values: ANI and DNIS, ANI only, DNIS only or DID only (default = no
value).
03 CLASS Equipment No.
If the CLASS type is chosen, the trunk must be assigned to a Caller ID circuit.
Enter the RCIU/RCIS equipment number as xxyyzz.
Possible values: xx = Cabinet 01(CTX100); 01~02 (CTX670 Basic); 01~07
(CTX670 Exp.)
yy = Slot 01~08 (CTX100); 01~10 (CTX670)
zz = Circuit 01~08
Notes
•
CLASS equipment numbers are required when assigning a trunk to a
RCIU/RCIS circuit.
•
It can also be used to display the equipment location of existing caller ID
circuit to trunk assignments. Example: If the trunk should be connected to a
caller ID circuit (RCIU/RCIS) in cabinet shelf 5, slot 2, circuit 3, enter
050203.