Applications, Tips and Tricks
CTX IP Telephone Programming Guidelines
A-6
Strata CTX Programming - Part 4: Appendices 04/03
CTX IP Telephone Programming Guidelines
Use the following guidelines to program your CTX IP Telephone.
Basic CTX IP Setup Using WinAdmin
1. Select System > Card Assignments (Program 100) to set the BIUP-M1A PCBs in the appropriate slots.
BIPU-M1A can only be installed in 16 channel card slots:
CTX100 slots 1~8; CTX670 Base slots 1~8; and CTX670 Expansion slots 1~6
Note
If the CTX is initialized (Program 900-01) after the BIPU-M1A is installed, the CTX assigns the
BIPU-1MA, code 021, to the appropriate card slots automatically.
2. Select IP Telephone > BIPU Configuration (Program151) to set BIPU-M1A IP address (check with the
Network Administrator for IP Address, subnet mask, etc.). The BIPU version number will be displayed
when the BIPU is operating and is connected on the same network as WinAdmin PC.
Note
If the CTX is initialized (Program 900-01) after the BIPU-M1A is installed, the CTX assigns the
BIPU-1MA default parameters as shown in
Table 1-6
on
page 1-5
.
3. Select Station > Assignments > Basic to assign PDNs to IP telephones (BIPU equipment numbers) if
this was not done during CTX system initialization. The WinAdmin PDN Range wizard can also be
used to assign PDNs to the BIPU channels.
Note
Currently IPT PDNs are listed as DKT, they will be listed as IPT in a future version of WinAdmin.
IP telephones are programmed exactly like DKTs, so any Program command used for DKTs can be
used for IPTs.
4. Select IP Telephone > Station IP Data (Program 250). Set “05 Station Terminal Authentication Mode”
to apply if the PDN assigned to a particular IP Telephone should be linked (reserved for) to that
telephone’s MAC address. Each telephone has a unique hard coded MAC address. This prevents other
IP telephones from using the reserved PDN when an IP telephone is moved.
Note
If IPT Authentication is applied/not applied in Program 250-05, it will override the IPT
Authentication setting in Program 150-02.
5. If multiple CTX systems with BIPU-M1As are connected to the IP network, Select IP Telephone >
System IP Data (Program 150), and set “09 IP CTX Identifier.”
Enter a CTX Node identifier if more than one CTX Node is on the IP Network. This can be the same as
the Qsig Network Node ID used for this system if it is in a CTX Qsig. Network - but the two IDs are not
related in software logic.
This ID must match the Node number programmed in the IP telephone using 369Hold-2, FB06 6.
6. Run all other CTX programs necessary to customize the features required for each IP Telephone. All
programs used to program Digital Telephones also apply to IP Telephones (Program 205 keystrips, 213
Add-on-Modules, Program 204 DKT Parameters, etc.).