Maintenance
Components
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
11-7
Ma
inte
nanc
e
Components
Prerequisite Program:
None
The following programs enable you to monitor the status of individual Strata CTX slots and ports.
This is the main system slot/port monitor. The Components screen allows each cabinet card slot and each
card slot port to be monitored, enabled or disabled. The card slot and port failure codes are provided in the
Table below.
➤
From the Program Menu, click
Maintenance > Components >
Cabinets 1~7.
Auto Fault Detection/Disable
When an error occurs in hardware resources used for a station or line, the Strata CTX system will make
them busy. In this case the Strata CTX system will automatically disable the card slot or card port (circuit
or channel). The Component Status/Control screen will indicate the card or port failure status with
“Disabled by Fault xx” where xx is the status code in the table below. When a digital telephone is disabled
the telephone’s LCD will display “Make Busy”. The station or line PCB can be disabled temporarily to
perform maintenance or parts replacements as well.
Note
The port or slot to which your programming phone is connected cannot be set to Make Busy.
The table on the next page states the possible error codes that can be displayed in the Status column of the
Main Components screen shown above.