74
Operational Reference
Genie_TS_Series GigE Vision Camera
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the
selected Line.
Counter Incremental
Source
counterIncrementalSource Select
the
event source which increments the
counter. The
provides details
and timing diagrams for the supported events.
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counts the number of Acquisition Start events.
Acquisition End
AcquisitionEnd Counts the number of Acquisition End events.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
Exposure End
ExposureEnd Counts the number of Exposure End events.
Readout Start
ReadoutStart Counts the number of Readout Start events.
Readout End
ReadoutEnd Counts the number of Readout End events.
Frame Start
FrameStart Counts the number of Frame Start events.
Valid Frame Trigger
ValidFrameTrigger Counts the number of Valid Frame Triggers.
Rejected Frame(s)
Trigger
InvalidFrameTrigger Counts the number of Rejected Frame(s) Trigger.
MultiFrame End Trigger
FrameBurstEnd Counts the number of multiframe end triggers.
Line 1
Line1 Counts the number of transitions on Line 1 (based on
the counterIncrementalLineActivation feature setting)
See Input Signals Electrical Specifications.
Line 2
Line2 Counts the number of transitions on Line 2 (based on
the counterIncrementalLineActivation feature setting)
Line 3
Line3 Counts the number of transitions on Line 3 (based on
the counterIncrementalLineActivation feature setting)
Line 4
Line4 Counts the number of transitions on Line 4 (based on
the counterIncrementalLineActivation feature setting)
Internal Clock
InternalClock The counter increments on each microsecond tick of
the device internal Clock.
Timer 1 End
Timer1End Counts the number of TimerEnd events.
1.00
Expert
DFNC
Counter Incremental Line
Activation
counterIncrementalLineActivation
Selects the counter signal activation mode. The
counter increments on the specified signal edge or
level.
Rising Edge
RisingEdge Increment the counter on the rising edge of the
selected I/O Line.
Falling Edge
FallingEdge Increment the counter on the falling edge of the
selected I/O Line.
Any Edge
AnyEdge Increment the counter on the falling or rising edge of
the selected I/O Line.
1.00
Expert
DFNC
Counter Duration
counterDuration
Sets the duration (or number of events) before the
CounterEnd event is generated.
1.00
Expert
DFNC
counterResetSource
Selects the signal source to reset the counterValue
Register. The counter then waits for the next
countStartSource signal or event (unless
countResetSource = countStartSource, which starts
immediately after reset).
Reset Cmd
Off Reset on reception of the Reset Icommand.
Acquisition Start
AcquisitionStart Reset on reception of the Acquisition Start.
Acquisition End
AcquisitionEnd Reset on reception of the Acquisition End.
Exposure Start
ExposureStart Reset on reception of the Exposure Start event.
Exposure End
ExposureEnd Reset on reception of the Exposure End event.
Readout Start
ReadoutStart Reset the counter on the reception of the Readout
Start event.
Readout End
ReadoutEnd Reset the counter on the reception of the Readout
End event.
Frame Trigger
FrameStart Reset on reception of the Frame Trigger.
Valid Frame Trigger
ValidFrameTrigger Reset on reception of the Valid Frame Trigger.
1.10
Expert
DFNC