Genie_TS_Series GigE Vision Camera
Operational Reference
73
Display Name
Feature & Values
Description
Device
Version
& View
Counter Selector
counterSelector
Selects the counter to configure.
Counter 1
Counter1 Select counter 1
1.00
Expert
DFNC
Counter mode
counterMode
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the Counter
can be configured.
Off
Off The selected Counter is Disabled
Active
Active The selected Counter is Enabled
1.00
Expert
DFNC
Counter Status
counterStatus
Returns the current state of the counter. (RO)
Counter Idle
CounterIdle The counter is idle.
The CounterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
1.00
Expert
DFNC
counterStartSource
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature of
the counterValue Register. If the countStartSource =
countResetSource, the counter resets then starts
again.
CounterReset Cmd
Off Counter Starts on the reception of the Counter Reset
Icommand.
Acquisition Start Cmd
AcquisitionStart Counter starts on the reception of the Acquisition
Start event.
Acquisition End
AcquisitionEnd Counter starts on the reception of the Acquisition End
event.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start
event
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End
event.
Readout Start
ReadoutStart Start the counter on the reception of the Readout
Start event.
Readout End
ReadoutEnd Start the counter on the reception of the Readout End
event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start
event.
Valid Frame Trigger
ValidFrameTrigger Counter starts on the reception of the Valid Frame
Trigger.
Rejected Frame Trigger
InvalidFrameTrigger Counter starts on the reception of the Invalid Frame
Trigger.
Line 1
Line1 Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Line 2
Line2 Counter starts on the specified transitions on Line 2
Line 3
Line3 Counter starts on the specified transitions on Line 3
Line 4
Line4 Counter starts on the specified transitions on Line 4
Timer 1 End
Timer1End Counter starts on the reception of the Timer End
event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter End
event.
1.10
Expert
DFNC
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable when
the counterStartSource feature selects a physical
Line.
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
1.00
Expert
DFNC