52
Operational Reference
Genie_TS_Series GigE Vision Camera
Auto-Gain Min Value
gainAutoMinValue
Sets the minimum gain multiplier value for the automatic
gain algorithm. The automatic gain function is an
amplification factor applied to the video signal to obtain
the auto-brightness target value.
< DFNC Expert >
all all all
Black Level Selector
BlackLevelSelector
Selects which Black Level to adjust using the
Black Level features.
< Beginner >
Analog
AnalogAll Sensor Dark Offset
all all all
BlackLevel
Controls the black level as an absolute physical value.
This represents a DC offset applied to the video signal, in
DN (digital number) units. The Black Level Selector
feature specifies the channel to adjust.
< Beginner >
all all —
Auto-Black Level
BlackLevelAuto
Enable the automatic black level adjustment function
and how it operates.
< Expert >
— —
V1.xx
Off Off
Function
Off
On Demand
OnDemand Function operates on BlackLevelAutoOnDemandCmd
Continuous
Continuous Function operates continuously
Auto-black Level On-Demand
Command
BlackLevelAutoOnDemandCmd
Enables an automatic black level adjustment process.
< Expert >
V1.xx
Automatic Black Level
Calibration Status
BlackLevelAutoCalibrationStatus Returns
the
current state of black level calibration.
< Expert >
— —
V1.xx
Calibrated
Calibrated The black level is calibrated.
UnCalibrated
UnCalibrated The black level is not calibrated.
On-Sensor FPN Calibration Mode OnSensorFpnCalibrationMode
Activation mode for the On-Sensor Fixed Pattern Noise
Calibration function.
< Expert >
— —
V1.xx
Off
Off FPN calibration Off
On Demand
OnDemand FPN calibration On Demand
Continuous
Continuous FPN calibration Continuous
On-Sensor FPN Calibration On-
Demand Comand
OnSensorFpnCalibrationOnDemandCmd
Enable an automatic On-Sensor Fixed Pattern Noise
Calibration process.
< Expert >
V1.xx
On-Sensor FPN Calibration
Status
OnSensorFpnCalibrationStatus
Returns the current state of the fixed pattern noise
calibration process.
< Expert >
— —
V1.xx
Calibrated
Calibrated The fixed pattern noise is calibrated
UnCalibrated UnCalibrated
The
fixed
pattern noise is not calibrated
MultiSlope Sensor Response
Mode
multiSlopeSensorResponseMode
Sets the enable state of the multi-slope response
mechanism on the sensor.
< DFNC Expert >
V1.10 - STD
all
—
Off
Off Disable the MultiSlopeSensorResponseMode feature.