142
Operational Reference
Genie_TS_Series GigE Vision Camera
Serial Port Control Category
The Serial Port control in CamExpert allows the user to select an available camera serial port and
review its settings. This section also describes the Genie TS Framework Virtual Serial Port Driver
and the use of the Genie TS serial port as an interface from an Ethernet network to a serial port
control system for other devices.
Features listed in the description table but tagged as
Invisible
are usually for Teledyne DALSA or
third party software usage—not typically needed by end user applications. Also important, Genie
TS cameras are available in a number of models implementing different sensors and image
resolutions which may not support the full feature set defined in this category.
Serial Port Control Feature Descriptions
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie TS capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
DeviceSerialPortSelector
Selects the serial port to control.
Serial Port 1
SerialPort1 First Serial Port available on the device
Serial Port 2
SerialPort2 Second Serial Port available on the device
1.10
Guru
Serial Port Control
deviceSerialPortControlMode
Specifies whether the device serial port is
controlled by the device itself or remotely
controlled by the host computer.
Remote Host Controlled
RemoteHostControlled Local serial port is controlled by the host
computer
In Camera Controlled
InCameraControlled Local serial port is controlled by the camera
itself
1.10
DFNC
Guru
Serial Port Signaling
deviceSerialPortSignaling
Displays the current serial port signaling
protocol in use by the device. This feature
selects the protocol if multiple types are
supported.
RS-232
RS232 Use RS-232 signaling protocol
RS-485
RS485 Use RS-485 signaling protocol
None
None No signaling protocol
1.10
DFNC
Expert
Serial Port Baud Rate
DeviceSerialPortBaudRate
Sets the baud rate used by the selected
device’s serial port. Available baud rates are
device-specific.
Baud 9600
Baud9600 Baud rate is 9600
1.10
Expert