STATus Subsystem
3–30
VX1410 IntelliFrame Instruction Manual
STATus:OPERation?
Returns the contents of the Operation Event register. A value of one in a bit
indicates the corresponding condition bit changed from false to true. Unused bits
always return a value of zero. The register is cleared by the *CLS command.
There is no command associated with this query.
Parameter
Query Response
Not applicable
<NR1>
Operation Status Word Bits
Definition
D0
CALibrating
D1
Not Used
D2
Not Used
D3
Not Used
D4
Not Used
D5
Not Used
D6
Not Used
D7
Not Used
D8
VXI Monitor
D9
Mainframe Power Down
D10
Not Used
D11
Not Used
D12
Not Used
D13
Not Used
D14
Not Used
D15
Not Used
Not Applicable
None
Reading the register clears it.