Getting Started
1–6
VX1410 IntelliFrame Instruction Manual
H
Option A3 Power cord for the external supply (Tektronix part number
161-0066-11)
H
Option A4 Power cord for the external supply (Tektronix part number
161-0066-12)
H
Option A5 Power cord for the external supply (Tektronix part number
161-0154-00)
H
Single-wide EMI panel fillers (Tektronix part number 333-4092-00)
H
Double-wide EMI panel fillers (Tektronix part number 333-4092-01)
H
EMI intermodule shields (Tektronix part number 337-4041-XX)
H
Backplane EMI DIN shields (Tektronix part number 337-4057-XX)
Selecting the Correct Power Cord and Fuse
The VX1410 IntelliFrame comes standard with two power cords and three fuses.
Before installing the mainframe, you must determine the correct fuse and power
cord for your application. Use the following information to determine the
appropriate power cord and line fuse for the VX1410 IntelliFrame. This
information is important to avoid overloading the power distribution system and
to comply with the National Electrical Code.
For card cage loads in the nonshaded region of Figure 1–1, use the power cord
with the 15 A plug (Tektronix part number 161-0213-XX) or the power cord
with the 20 A plug (Tektronix part number 161-0218-XX). For high card cage
loads combined with low input line voltages (shaded region), use only the power
cord with the 20 A plug.