System Subsystem
3–96
VX1410 IntelliFrame Instruction Manual
SYSTem:FACTory
This command sets the VX1410 IntelliFrame settings (except the communication
settings) to the factory default values. Table 3–16 lists the impacted commands
and their factory default settings.
Table 3–16: VX1410 IntelliFrame Factory Default Settings
Command
Settings
DISPlay[:WINDow]:TEXT:[DATA]
“SYSTEM OK”
STATus:OPERation:ENABle
0
STATus:OPERation:VXIMonitor:ENABle
32767
STATus:QUEStionable:BLOWer:ENABle
32767
STATus:QUEStionable:ENABle
0
STATus:QUEStionable:FILTer:TINTerval
4000
STATus:QUEStionable:TEMPerature:ENABle
32767
STATus:QUEStionable:TEMPerature:LIMit
AMBient: 55
DELTaN: 10
STATus:QUEStionable:VOLTage:ENABle
32767
STATus:QUEStionable:VOLTage:PTR
32743
STATus:QUEue:ENABle
(–1999:1000)
SYSTem:ERRor:ENABle
(–1999:1000)
SYSTem:SYSReset
0
VXIMonitor:REPeat
0
VXIMonitor:TINTerval
10
*ESE
0
*PSC
0
*SRE
0
Parameter
Query Response
Not Applicable
Not Applicable
Not Applicable
None
Syntax
Parameters
Reset Value
Errors and Events