Product:
492 Ser.1
Date: 2-25-85
Change Reference: C102/285
g. Set the front-panel controls as follows:
2701
13 dB
492
RESOLUTION BANDWIDTH 100 kHz
VIDEO FILTER (WIDE)
on
h. Measure and record for reference the bandwidth of the 2 MHz
signal at a point 6 divisions down from the top graticule line.
i. Adjust R1013 on the 1st LO Driver board for approximately
-1.0 V at TP1011.
NOTE
During the following procedure, do not allow this voltage
to go more positive than 0.1 V.
j .
Bring the Start Spur signal to center screen with the CENTER
FREQUENCY control. Frequency readout will indicate 0.00 MHz.
NOTE
For the least overall signal variations with frequency
(flatness) ,
the adjustments on the 1st Converter must be
made in conjunction with R1013 (bias for bands 1, 2, and3) .
k. Alternately adjust R1013 and the adjustments on the 1st
Converter (see Fig.4-23A) until the bandwidth, at the 6 dB point,
matches the bandwidth of the previously displayed 2 MHz signal.
NOTE
It will be necessary to alternate between the above
adjustments to decrease the amplitude of the start
spur. While this is being done, assure that the
voltage at TP1011 does not 1.0 V.
It will not be possible to null the start spur to
a point where the top of the signal will be on screen.
To assure that the signal meets the specification
(-13 dBm) , the bandwidth is matched to the bandwidth
of the previously displayed 2 MHz signal. Do not
adjust the start spur lower than -13 dBm.
1. Remove all test leads from the test setup.
Page 5 of 5