![Tektronix 492, 492P Service Manual Download Page 127](http://html1.mh-extra.com/html/tektronix/492-492p/492-492p_service-manual_1077914127.webp)
Maintenance—492/492P Service Vol. 1 (SN B030000 & up)
3. Unsolder the ground wire from the front-panel casting
and unplug the crt cables at their respective board connec
tions (high voltage module, deflection amplifier, and Z-Axis
board).
4. Slide the crt, with its shield, out through the front
panel.
5. Remove the crt shield as follows:
a) remove the tube base cap and unplug the socket;
b) remove the two side screws that hold the upper shield
in place; then remove the shield;
c) loosen the screws that clamp the plastic bracket
around the crt; then remove the bracket.
Replacement
1.
Install the plastic bracket so the back on the clamp is
5.07 inches from the back of the crt socket guide.
2.
Replace the crt shield plus the socket and base shield
by reversing the removal procedure. The finished crt assem
bly length, with cap installed, must equal 11.05 inches. If it is
longer, the assembly may short circuit the Log Amplifier cir
cuit board when it is installed.
3.
Install crt with shield assembly into the front panel.
Install bezel and tighten the four mounting screws.
Do not reposition the front-panel blue plastic crt hold
ers. They have been factory aligned so the crt assem
bly seats properly. Visually inspect to ensure that the
crt assembly dears the circuit board components.
4.
Reconnect cables to their respective board connec
tors and resolder the ground lead to its terminal. Replace crt
light filter and snap-in bezel.
Repairing the Crt Trace Rotation Coil
The trace rotation coil is part of the crt assembly. If the
coil is damaged beyond repair, the crt with the coil must be
replaced.
If the “finish” (red) lead is broken, remove the tape and
unwind one or two turns so it can be respliced and soldered
to the lead wire. Rewind and retape.
If the “start” (black) lead is broken and the lead is too
short to resplice, attempt to fish out the broken end so one
or two turns can be unwound. Resplice and solder to the
lead; then rewind and retape.
Front-Panel Assembly
The front-panel assembly does not have to be removed
to replace any of the push buttons. Refer to Replacing
Front-Panel Push Buttons procedure that follows. The crt is
removed with the front-panel assembly.
Removal
1.
Unscrew and remove the mounting nuts and washers
for the RF INPUT, EXT MIXER, plus the two 1 st and 2nd LO
OUTPUT connectors.
2.
Remove the two screws that hold the front panel to
the RF deck (center and left side).
3.
Unplug the CAL OUT coaxial cable from the 3rd Con
verter; then disconnect the five crt cables from the Z-
Axis/RF Interface, High Voltage module, and Deflection
Amplifier.
4.
Looking at the top of the instrument, remove the one
screw that holds the front panel to the side extrusion, be
tween the crt and the right side of the instrument.
5.
Now set the instrument on its side and remove the
four screws that hold the front panel to the side rails.
6
. Pull the front panel up and off the Mother board.
Replacement
Replace the front panel by reversing the removal
procedure.
Front-Panel Board
NOTE
A replacement Front-Pane! board comes with switch
es and controls for all Options (01, 02, 03, etc.). Be
fore replacing an existing board, remove the switches
and controls on the new board that are not used on
the existing instrument.
4-14
REV AUG 1981