Specification—492/492P Service Vol. I (SN B030000 & up)
Table 1-1 (cont)
Characteristic
Performance Requirement
Supplemental Information
1st LO and 2nd LO
Provides access to the output of the respective
local oscillators (1st LO +7.5 dBm minimum to
a maximum of +15 dBm. 2nd LO —22 dBm
minimum to a maximum of +15 dBm). These
ports must be terminated in 50 Ω at all times
VERTICAL
0.5 V, ± 5% of signal per division of video above
and below the centerline.
Source impedance approximately 1 kQ
HORIZ OUT
0.5 V/Div either side of center.
Full range -2 .5 V to +2.5 V, ±10%
Source impedance approximately 1 kn
PEN LIFT
IF OUT
TTL compatible, nominal + 5 volts to lift pen
Access to the 10 MHz IF. Output level is ap
proximately — 16 dBm for a full screen signal at
—30 dBm reference level. Nominal impedance
approximately 50 Ω
IEEE Std 488-1978 Port (GPIB)
492P
In accordance with IEEE 488 standard
PROBE POWER
Provides operating power for active
probe systems. Output voltages and
pin-out are shown in Fig. 1-1.
GENERAL CHARACTERISTICS
Sweep
Sweep Time
20
m s
/ D
i v
to 5 s/Div in 1 -2-5 sequence
(10s/Div in Auto)
Triggered, auto, manual, and external
Accuracy
±5%
Triggering
>
2 . 0
division of signal for internal,
and 1.0 V peak minimum for
external
Internal, external, free run, and single
sweep. Internal is ac coupled (15 Hz to
1 MHz)
Crt Readout
Displays: Reference level, frequency, vertical
display mode, frequency span/div, frequency
range,
resolution
bandwidth,
and
RF
attenuation
POWER REQUIREMENTS
Characteristic
Description
Input Voltage
90 to 132 Vac or 180 to 250 Vac, 48 to 440 Hz
Power
Power (Options 01, 02, 03)
At 115 V, 60 Hz; 210 watts maximum, 3.2 amperes
Leakage Current
5 mA peak
NOTE
If power to this instrument is interrupted, it may be necessary to re-initialize the microcomputer; when power is
restored, turn the POWER switch O ff for 5 seconds then back On.
REV NOV 1982
1-11