52
Operation via the Control Panel
9.2.2 Indications on the display
The display can in++ or - - - if a parameter is out
of range. In the VSD there are parameters which are
dependent on other parameters. For example, if the
speed reference is 500 and the maximum speed value
is set to a value below 500, this will be indicated with
+++ on the display. If the minimum speed value is set
over 500, - - - is displayed.
9.2.3 LED indicators
The symbols on the control panel have the following
functions:
Fig. 63 LED indications
9.2.4 Control keys
The control keys are used to give the Run, Stop or Reset
commands directly. As default these keys are disabled,
set for remote control. Activate the control keys by
selecting Keyboard in the menus Ref Control [214] and
Reset Ctrl [216].
If the Enable function is programmed on one of the dig-
ital inputs, this input must be active to allow Run/Stop
commands from the control panel
.
9.2.5 The Toggle and Loc/Rem Key
This key has two functions: Toggle and
switching between Loc/Rem function.
Press one second to use the toggle func-
tion
Press and hold the toggle key for more than five sec-
onds to switch between Local and Remote function,
depending on the settings in [2171] and [2172].
When editing values, the toggle key can be used to
change the sign of the value, see section 9.5, page 54.
Toggle function
Using the toggle function makes it possible to easily
step through selected menus in a loop. The toggle loop
can contain a maximum of ten menus. As default the
toggle loop contains the menus needed for Quick
Setup. You can use the toggle loop to create a quick-
menu for the parameters that are most importance to
your specific application.
Add a menu to the toggle loop
1. Go to the menu you want to add to the loop.
2. Press the Toggle key and keep it pressed while
pressing the + key.
Delete a menu from the toggle loop
1. Go to the menu you want to delete using the toggle
key.
2. Press the Toggle key and keep it pressed while
pressing the - key.
Delete all menus from the toggle loop
1. Press the Toggle key and keep it pressed while
pressing the Esc key.
2. Confirm with Enter. The menu Preferred view [100]
is displayed.
Default toggle loop
Fig. 64 shows the default toggle loop. This loop con-
tains the necessary menus that need to be set before
starting. Press Toggle to enter menu [211] then use the
Table 19
LED indication
Symbol
Function
ON
BLINKING
OFF
POWER
(green)
Power on
----------------
Power off
TRIP (red)
VSD tripped
Warning/Limit
No trip
RUN
(green)
Motor shaft
rotates
Motor speed
increase/
decrease
Motor
stopped
NOTE: If the control panel is built in, the back light of the
display has the same function as the Power LED in Table
19 (Blank panel LEDs).
Table 20
Control keys
RUN L:
gives a start with
left rotation
STOP/RESET:
stops the motor or resets
the VSD after a trip
Run
Green
Trip
Red
Power
Green
RESET
RUN R:
gives a start with
right rotation
NOTE: It is not possible to simultaneously activate the
Run/Stop commands from the keyboard and remotely
from the terminal strip (terminals 1-22).
NOTE: Do not keep the Toggle key pressed for more than
five seconds without pressing either the +, - or Esc key,
as this may activate the Loc/Rem function of this key
instead. See menu [217].
Table 20
Control keys
LOC/
REM
Summary of Contents for F33 Series
Page 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Page 3: ......
Page 33: ...30 Getting Started...
Page 51: ...48 Main Features...
Page 53: ...50 EMC and Machine Directive...
Page 59: ...56 Operation via the Control Panel...
Page 65: ...62 Serial communication...
Page 159: ...156 Troubleshooting Diagnoses and Maintenance...
Page 165: ...162 Options...
Page 179: ...176 Technical Data...
Page 187: ...184 Menu List...