
Functional Description
131
11.5.6 Virtual Connections [560]
Functions to enable eight internal connections of com-
parator, timer and digital signals, without occupying
physical digital in/outputs. Virtual connections are
used to wireless connection of a digital output function
to a digital input function. Available signals and control
functions can be used to create your own specific func-
tions.
Example of start delay
The motor will start in RunR 10 seconds after DigIn1
gets high. DigIn1 has a time delay of 10 s.
Virtual Connection 1 Destination [561]
With this function the destination of the virtual connec-
tion is established. When a function can be controlled
by several sources, e.g. VC destination or Digital Input,
the function will be controlled in conformity with “OR
logic”. See DigIn for descriptions of the different selec-
tions.
Communication information
Virtual Connection 1 Source [562]
With this function the source of the virtual connection
is defined. See DigOut 1 for description of the different
selections.
Communication information
Virtual Connections 2-8 [563] to [56G]
Same function as virtual connection 1 [561] and [562].
Communication information for virtual connections 2-8
Destination.
Communication information for virtual connections 2-8
Source.
Menu
Parameter
Setting
DigIn1
Timer 1
VIO 1 Dest
RunR
[562]
VIO 1 Source
T1Q
[641]
Timer1 Trig
DigIn 1
Timer1 Mode
Delay
Timer1 Delay
0:00:10
NOTE: When a digital input and a virtual destination are
set to the same function, this function will act as an OR
logic function.
Default:
Off
Selection:
Same selections as for Digital Input 1,
menu [521].
Modbus Instance no/DeviceNet no: 43281
Profibus slot/index
169/185
Fieldbus format
UInt
Modbus format
UInt
Stp
Off
A
Default:
Off
Selection:
Same as for menu [541].
Modbus Instance no/DeviceNet no: 43282
Profibus slot/index
169/186
Fieldbus format
UInt
Modbus format
UInt
Modbus Instance no/DeviceNet no:
43283, 43285, 43287,
43289, 43291, 43293,
43295
Profibus slot/index
169/ 187, 189, 191,
193, 195, 197, 199
Fieldbus format
UInt
Modbus format
UInt
Modbus Instance no/DeviceNet no:
43284, 43286, 43288,
43290, 43292, 43294,
43296
Profibus slot/index
169/ 188, 190, 192,
194, 196, 198, 200
Fieldbus format
UInt
Modbus format
UInt
Stp
Off
A
Summary of Contents for F33 Series
Page 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Page 3: ......
Page 33: ...30 Getting Started...
Page 51: ...48 Main Features...
Page 53: ...50 EMC and Machine Directive...
Page 59: ...56 Operation via the Control Panel...
Page 65: ...62 Serial communication...
Page 159: ...156 Troubleshooting Diagnoses and Maintenance...
Page 165: ...162 Options...
Page 179: ...176 Technical Data...
Page 187: ...184 Menu List...