Service and maintenance of machine
241
Giga-Vitesse CFS 3602 - 4402, Giga-Vitesse CFS 3602 DO - 4402 DO 03.18
8.5.8
Change gear lubricant oil
1.
Align the machine in horizontal position.
2.
Place a drip tray beneath the gearbox.
The tray's capacity must at least be equivalent to the filling quantity.
3.
Unscrew the oil drain plug.
The gear lubricant oil drains off.
4.
Unscrew the oil filling screw.
5.
Wait for the oil to stop draining out of the oil drain opening.
6.
Screw the oil drain plug in again and tighten it. Use sealant.
7.
Fill the specified oil quantity in through the oil filler neck.
8.
Clean the oil filling screw and screw it in.
9.
Check the oil level after 5 service hours.
The oil level must be visible at the oil inspection plug.
Summary of Contents for Giga-Vitesse CFS 3602
Page 2: ......
Page 4: ...Bad Laer den 26 03 2018 Dipl Kfm W Strautmann Managing Director...
Page 306: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 306 Fig 174...
Page 309: ...Circuit diagrams 309 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 310: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 310...
Page 313: ...Circuit diagrams 313 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 314: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 314...
Page 317: ...Circuit diagrams 317 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 318: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 318...
Page 320: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 320...
Page 326: ......