Operation
Giga-Vitesse CFS 3602 - 4402, Giga-Vitesse CFS 3602 DO - 4402 DO 03.18
202
The sensor for the folding drawbar is recalibrated.
7.
Test the sensor calibration: Use the
key to move the folding drawbar to the upper end
position.
The
nominal reading
is 100 %
8.
Use the
key to slightly lower the drawbar.
The
nominal reading
is 90 % - 99%
9.
Use the
key to move the folding drawbar to the lower end position.
The
nominal reading
is 0 %.
10.
Use the
key to slightly lift the drawbar.
The
nominal reading
is 1 % - 10 %.
11.
Press the
key.
The last run working menu is displayed.
If the actual values do not match the nominal values, repeat the
calibration.
Summary of Contents for Giga-Vitesse CFS 3602
Page 2: ......
Page 4: ...Bad Laer den 26 03 2018 Dipl Kfm W Strautmann Managing Director...
Page 306: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 306 Fig 174...
Page 309: ...Circuit diagrams 309 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 310: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 310...
Page 313: ...Circuit diagrams 313 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 314: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 314...
Page 317: ...Circuit diagrams 317 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 318: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 318...
Page 320: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 320...
Page 326: ......