GuardOne
®
· Manual · 7
English
O
ve
rv
iew o
f t
h
e G
u
a
rd
O
n
e
®
W
o
rk
st
a
ti
o
n
/S
c
o
p
e o
f D
e
li
ve
ry
Spare parts must only be ordered from the
manufacturer
S
tarlab.
For further information, contact your local
S
tarlab sales representative.
Top housing unit
The top housing is a preinstalled unit in which the blower motor, pre- and HEPA filter are already installed, provided that it is the Laminar Flow
model of the GuardOne® Workstation.
Fig. 3: Pre-installed top housing unit of the model Laminar Flow, size 32“
1 Touchscreen display with graphical user interface
2 LED light panel
3 Plastic rivets
4 Filter grid with HEPA filter inside
5 UV bulb holder
6 UV lamp
7 Recess
8 Coarse- and pre-filter
9 Main power switch, main power connection and
USB connection
The top housing unit contains following components:
› Coarse- and pre-filter consisting of a filter cover and filter fleece on the roof
- On the roof of the top housing unit there is access to the pre-filter.
- Protected by a removable coarse filter, the pre-filter can easily be reached.
› Integrated HEPA filter
- The HEPA filter is located in the interior of the top housing unit.
- The life time of the HEPA filter is 600 days.
› Safety contact in form of a magnetic switch in the inside
- Like the front door, the top housing unit can be opened at its front side.
- It is equipped with a magnetic switch that automatically switches off the airflow and the touchscreen display when the top housing flap is open.
› UV light bulb holder in the back underneath the HEPA filter
- The GuardOne® Workstation uses UV light with a fixed wavelength of 254 nm for decontamination and sterilization of the working area.
- Depending on the model, one or two UV lamps marked with a serial number are included. The UV lamps must be installed in the bulb
holders after the assembly of the glass chamber and the top housing unit.
- The bulb holder for the UV lamp protrudes a few centimetres from the top housing unit.
- The life time of the UV lamps is 9000 hours.
› LED light panel in the front underneath the HEPA filter
- The LED light panel is pre-installed.
- Depending on the photosensitivity of the samples, you can switch the LED light on and off and change the settings for LED brightness or
the LED colour between normal white and red.
› Touchscreen display with graphical user interface on the front
- The operating unit is located on the front side. The GuardOne® Workstation is operated via a touchscreen display with the graphical user
interface.
- The display with the graphical user interface can be used to set the settings for the airflow, the LED and UV light. The display also
provides information about the manufacturer and health of the GuardOne® Workstation.
› Main power switch, main power connection and USB connection at the back
- The main power switch and connection as well as a USB connection are located on the back. The latter can be used for installing software
updates.
› Recess in the roof to keep the front door open to clean or maintain the PC glass chamber
- When the front door is folded up, the handle can be placed in the recess to prevent slipping.
› Plastic rivets, thumbscrews and two cables in a separate bag
- For assembly, plastic rivets, thumbscrews and two cables are included.
Summary of Contents for GuardOne
Page 54: ...54 GuardOne Bedienungsanleitung...
Page 106: ...106 GuardOne Manuel...
Page 158: ...158 GuardOne Manuale...
Page 210: ...210 GuardOne Manual...
Page 211: ...GuardOne Manual 211 Notes...