Standards used in development of the pump
The following standards were used in whole or part in the development of the pump.
Medical Electrical Equipment
EN 60601-1 (1990),
Medical Electrical Equipment, Part I: General Requirements for Safety.
Amendment A1 (1993) Amendment A13 (1996) Amendment A2 (1995).
EN 60601-2-24 (1998),
Medical Electrical Equipment, Part 2-24: particular Requirements for Safety of
Infusion Pumps and Controllers.
EN 60601-1-4 (1996),
Medical Electrical Equipment, Part 1-4: General Requirements for Safety—
Collateral Standard: Programmable electrical medical systems. Amendment A1: 1999.
IEC 60601-1 (2nd Edition, 1988),
Medical Electrical Equipment, Part 1: General Requirements for
Safety. Amendment 1 (1991) Amendment 2 (1995).
IEC 60601-1-4 (2000),
Medical Electrical Equipment, Part 104: General Requirements for Safety—
Collateral Standard: Programmable electrical medial systems.
IEC 60601-2-24 (1998),
Medical Electrical Equipment, Part 2-24: Particular Requirements for Safety of
Infusion Pumps and Controllers.
CAN/CSA-C22.2 601.1-M90,
Medical Electrical Equipment, Part 1: General Requirements for Safety -
November 1990 (Canadian Deviations to IEC 60601-1) Update No. 2 (November 2003).
Electromagnetic Compatibility
RTCA/DO -160E (2004),
Radiated Emissions Only, Category M Limit.
EN 60601-1-2 (2001),
Medical Electrical Equipment, Part 1-2: General Requirements for Safety—
Collateral Standard: Electromagnetic Compatibility—Requirements and Tests.
IEC 60601-1-2 (Edition 2.1, 2004-11),
Medical Electrical Equipment, Part 1-2: General Requirements
for Safety—Collateral Standard: Electromagnetic Compatibility—Requirements and Tests.
IEC 61000-4-2 (2001),
Electromagnetic Compatibility (EMC), Part 4-2: Testing and measurement
techniques. Electrostatic Discharge immunity test.
IEC 61000-4-3 (2006),
Electromagnetic Compatibility (EMC), Part 4-3: Testing and measurement
techniques. Radiated, radio frequency, electromagnetic field immunity test.
IEC 61000-4-4 (2004),
Electromagnetic Compatibility (EMC), Part 4-4: Testing and measurement
techniques. Electrical fast transient/burst immunity test.
IEC 61000-4-5 (2005),
Electromagnetic Compatibility (EMC), Part 4-5: Testing and measurement
techniques. Surge immunity test.
IEC 61000-4-6 (2004),
Electromagnetic Compatibility (EMC), Part 4-6: Testing and measurement
techniques. Immunity to conducted disturbances, induced by radio-frequency fields.
IEC 61000-4-8 (2001),
Electromagnetic Compatibility (EMC), Part 4-8: Testing and measurement
techniques. Power frequency magnetic field immunity test.
IEC 61000-4-11 (2004),
Electromagnetic Compatibility (EMC), Part 4-11: Testing and measurement
techniques. Voltage dips, short interruptions and voltage variations immunity test.
CISPR11 (2004),
Limits and methods of measurement of electromagnetic disturbance characteristics
of industrial, scientific and medical (ISM) radio frequency equipment. Amendment 1 (1999)
Amendment 2 (2002).
EN 45502-1 (1998),
Active implantable medical devices. Part 1. General requirements for safety,
marking and information to be provided by the manufacturer.
EN 55011 (1998),
Industrial, scientific and medical (ISM) radio frequency equipment—Radio
disturbance characteristics—Limits and methods of measurement. Amendment 1 (1999),
Amendment 2 (2002)