Protection
IMx-M Manager
SKF Multilog On
-Line System IMx-M
2 - 73
User Manual
hidden files, folders, and drives". It is done on the computer via
Organize
\Folder and search options\View\Hidden files and folders.
–
Enter the PIN code of the already existing configuration in the
protection module, NOT the PIN code of the new configuration that
will be downloaded.
If there is no PIN code, then"0000" (four zeroes) may be entered .
–
If the download is successful, the protection module will restart with
the new configuration and the new PIN code will take effect.
–
Check that there are no circuit faults before disarm is released.
–
Check that there are no channel alarms before disarm is released.
–
The protection configuration update process can take about one
minute.
•
Update Firmware
downloads a protection firmware to the protection
module to which a USB is connected.
Important - System must be set in slot disarm mode before the protection
firmware update procedure takes place. Be sure to read "Disarm" chapter
thoroughly and understand it.
Important - See also chapter "Relays on Relay Modules" and "Behavior of Slot
Status Relays" for details when shared relays are used.
Important - Do not turn off the power during the protection firmware update
process.
–
Select a "
.a48"
firmware file to be downloaded.
–
Enter the PIN code of the already existing configuration in the
protection module.
If there is no PIN code, then "0000" (four zeroes) may be entered.
–
When the download is successfully completed, the protection module
will reboot with the newly updated firmware version.
–
It is strongly recommended to check the version of the firmware to
ensure the correct version after each firmware update by using a
diagnostic command "
intd0
" as described in Protection Part
–
It is also strongly recommended to have the same version of the
firmware for all the slots within the rack.
•
Send CF Command
displays all the circuit faults along with descriptions of
the current slot (all channel and relay configurations).
•
Lock Display Window
is a toggle button which loc
ks/unlocks the contents
on the output display window. This can be useful if a user wants to copy