SKF Multilog On
-Line System IMx-M
7 - 1
User Manual
7
Technical Data
Environmental
•
19" rack mounted, 6U high
•
Size (height x width x depth): 266 x 482 x 240 mm (10.5 x 19 x 9.4 in.)
•
Weight: 13,6 kg (30 lb.) for a fully equipped rack
•
Temperature range:
–
−
20 to +70 °C (
−
4 to +158 °F
) in storage
–
−
20 to +65 °C (
−
4 to +149 °F
) in operational mode
•
Encapsulation IP 20
•
Humidity 95% (relative) non-condensing
•
Overvoltage category
II
•
Pollution degree 2
•
Altitude maximum 2 000 m (6 562 ft.)
Rack
•
2 Power Supply Units
•
4 condition monitoring modules and 4 protection modules (always mounted in
pairs)
•
3 relay modules
•
Screw terminals, RJ45 and D-sub connectors on the back side
•
Event Log: minimum of 1 400 latest events can be stored on each CMM + PRM slot
Power Supply
•
90 to 240 VAC, 47 to 63 Hz, 300 W maximum output
•
Redundant option, individual mains terminals