9
The anti-twist mechanism is firmly situated in the lock and keeps the
bolt sensor in its position.
7.6.4.5 Step 3: Preparing to install the outer fitting
1. Place outer cover (2) loosely onto the outer fitting (4). Notice that the
outer cover can only be placed onto the fitting in one direction.
9
The outer cover is positioned flush on the outer fitting but without
fastening it.
2. Push inlay (1) onto the outer handle (3) from the short side. Ensure that
the black side of the inlay is turned towards the door.
3. Insert outer fitting horizontally into the outer fitting in the direction that
you require (DIN left or DIN right).
9
The outer handle is placed in the outer fitting without being
fastened.
4. Position handle fastener piece (5) on the side which will later face the
door, as in the diagram below, and fasten with a spanner in a clockwise
direction (about 75º until you feel resistance).
9
75°
1
2
4
-45°
3
9
The outer handle is now firmly attached to the outer fitting and
cannot be removed from the outside when in use.
5. Check the handle mechanism to ensure it opens easily.
9
The outer handle must return to its home position of its own accord.
Repeat the procedure described in this section if the outer handle
should catch and not open correctly.
IMPORTANT
For easier installation, the cover can also be pushed over the inlay later in
chapter "
Step 6: Fastening the covers [
7.6.4.6 Step 4: Installation of fittings
1. Position installation tool (A) through the profile cylinder opening in the
door lock, so that the plug remains on the outer side.
2. Push the inside fitting spindle through the retainer slot in the door's
mortise lock, so that the fitting is flush with the door.
3. Cables for fastening screw and bolt buttons and the installation tool
must be fed beneath the anti-twist mechanism to the inner side.
9
The inside fitting is now firmly placed flat against the door. The
cables and installation tool run downwards on the inside of the door.
If a two-wire cable should be too short, a extension/adapter cable
can be used.
4. Use the installation tool to connect the four-wire cable.
SmartHandle
(Manual)
7. Installation (manual)
72 / 136