7.9.7 Diagrams for Scandinavian Oval
Figure 2:
Handle fastener piece
Figure 3:
Handle fastener piece open
Figure 4:
Handle fastener piece closed
Figure 5:
Fastener piece - correct position for
the handle fastener piece when
closed
Figure 6:
Figure 7:
Tab. 5:
Diagrams showing installation
7.9.8 Storage mode for Scandinavian Oval
1. Disconnect the 3-pole cable from the inside fitting to the 3-pole cable
from the outer fitting. If necessary also disconnect the cable of the
LockNode from the inside fitting.
2. Hold the inside and outer fittings firmly while pulling them away from
one another horizontally.
3. If necessary, loosen the hexagon screw in the inside door handle, but
ensure that you only unscrew a little, so that the screw remains in the
handle.
4. Remove the inside handle from the inside fitting.
Fitted to the door:
IMPORTANT
General instructions: Depending on the handle model, it may not be pos-
sible to remove the inlay immediately In such a case, push the inlay through
the opening in the cover and remove the cover. The inlay remains on the
handle and cannot be removed until the handle is dismounted.
Follow the same steps as for installation but in reverse order.
7.10 SmartHandle Hybrid
SmartHandle 3062 with hybrid authentication
(e.g active transponder and
passive smart cards/smart tags)
and SmartHandle 3062 with exclusively
passive authentication
(e.g. passive card)
are installed in the same way as
regular variants:
SmartHandle
(Manual)
7. Installation (manual)
93 / 136