7.5.4.8 Step 6: Fastening the covers
Outer and inside covers are mounted in the same way:
1. Carefully press cover onto the door. Ensure that the cover is positioned
flat against the door without a gap and no cables are outside the cover.
2. Click inlay carefully into the outer cover, which is still pressed against
the door.
7.6 Conventional fastening system for DoorMonitoring
7.6.1 Contents of packaging
2 x inlays
2 x covers
1 x outer fitting
1 x inside fitting
1 x outer handle (including lock ring)
1 x inside handle (including hexagon screw)
2 x sleeves
2 x fastening screws
1 x fire retardant inlay (in versions for fire retardant doors only)
1 x quick start guide
1 x installation tool for inlay
1 x fastening screw sensor
1 x bolt sensor
1 x Installation tool for bolt sensor
1 x Installation tool for four-wire cable
1x extension cable (2-pole)
(2x for L version for doors over than 79 mm
thickness)
1 x anti-twist mechanism
1 x drilling template
7.6.2 Tools required
The following tools are required for installation and are not included in the
supplied package:
Allen key (3 mm) to fit handle.
Cross-tip screwdriver type PH2 to fit mounting screw (battery
screwdriver recommended).
SmartHandle
(Manual)
7. Installation (manual)
66 / 136