IMPORTANT
Required screw length = door thi 4 mm. The tolerance is ± 1 mm.
9. The outer fitting (4) is mounted from the outer side of the door. Push
the cable from the outer fitting (4) through the small, upper hole in the
adapter plate (6).
10. Place the adapter plate (6) on the inside surface of the outer fitting (4),
so that it is flush with the fitting.
11. Use the three screws (7) to fasten the adapter plate (6) to the outer fit-
ting and then tighten firmly by hand (about 5-7 Nm).
12. Push the cable from the outer fitting through one of the two upper holes
in the mortise lock (8).
13. Push the outer fitting (4) onto the door, making sure that the cable does
not get caught or damaged in any other way.
14. Hold the outer fitting (4) firmly and then press the adapter plate (9)
against the door from the inside.
15. Use the four screws (10) to join the adapter plate (9) with the outer fit-
ting (4) from the inside, ensuring that the fitting can still move freely.
16. Position the fitting parallel to the door leaf; otherwise, you may not be
able to mount the inside fitting (11). If this is the case, you will need to re-
align the fitting.
17. Fasten the screws (10) until the adapter plate (9) lies flat against the
door.
18. The inside fitting (11) is mounted onto the inner surface of the door.
Push the inside fitting (11) spindle through the mortise lock's retainer slot
and push the inside fitting (11), so that it is flush on the door. In doing so,
push the 2-pole cable through the cylinder opening in the mortise lock
and ensure that it does not get caught.
19. Press outer and inside fittings together, so that they are both flush
against the door.
20.Press the electronics module cover lid in the inside fitting carefully out
of its bracket and fold back horizontally. Make sure that the electronics
are not exposed to mechanical load and are not damaged in any other
way.
21. Carefully remove the lower battery (13) from the holder. Use clean
gloves free of fat or grease to handle batteries.
22. Use the two screws (12) to fasten the inside fitting (11) to the adapter
plate (9), using about 5-7 Nm of force.
SmartHandle
(Manual)
7. Installation (manual)
87 / 136