5. Push plug out horizontally, directly beneath the anti-twist mechanism,
and to the inner side. The outer fitting must be attached to the door at
the same time.
6. Attach outer fitting onto the door from the outside and feed the two
sleeves (X1) into the drilled holes through the outer fitting.
7. Fasten the two screws (X2) to the sleeves via the inside fitting. Ensure
that the fitting is positioned in parallel to the door.
9
Inside and outer fitting are now firmly joined together flat against the
door.
8. Connect cables. The two two-pole cables and the four-pole cable are
to be properly connected to one another.
The two-pole cables can be
connected to one another as desired.
9. Lay cables in such a way that the cover can be easily fitted. Make sure
that you do not crush the cables.
7.6.4.7 Step 5: Installing the inside handle
1. Position the inside cover (11) on the inside fitting without fastening it.
Notice that the cover can only be placed onto the fitting in one direction.
9
The cover is positioned flush on the inside fitting but without
fastening it.
2. Push inlay (11) onto the inside handle retainer. Ensure that the black side
of the inlay is turned towards the door.
3. Insert inner handle horizontally into the inside fitting in the direction you
require (DIN left or DIN right).
9
The inside handle is placed in the inside fitting without being
fastened.
4. Tighten the headless screw to fasten inside handle.
9
The inner door handle is now firmly linked to the SmartHandle.
5. Check the handle mechanism to ensure it opens easily.
9
Repeat the procedure described in this section if the handle should
catch or jam!
IMPORTANT
For easier installation, in most cases the cover can be pushed over the inlay
later in chapter "
Step 6: Fastening the covers [
7.6.4.8 Step 6: Fastening the covers
Outer and inside covers are mounted in the same way:
1. Carefully press cover onto the door. Ensure that the cover is positioned
flat against the door without a gap and no cables are outside the cover.
SmartHandle
(Manual)
7. Installation (manual)
73 / 136