8 Programming
SmartHandles do not need to be taken out of their packaging for
programming as they can be programmed while still in the box.
8.1 SmartHandle G1
LSM version 3.0 or higher and a Smart CD G2 programming device or newer
are required for its use.
Please select 'Locking Cylinder G1' as the locking type in the case of
SmartHandle G1. SmartHandle is detected and incorporated into the
locking plan during programming and then displayed in the lock
configuration. All the same functions as in TN4 cylinders (G1) are available.
Open the management and programming software (LSM) and select in
the database.
Select locking system (if several are available)
Select 'New lock'
Select 'Locking Cylinder G1' as lock type
Give the lock a name
You can select "Section" as an option
Confirm by pressing 'Accept.'
Highlight the lock (so that it appears in BLUE)
Place the SmartHandle at a distance of about 10 cm from the
programming device, fitting the cover on the electronics side if possible.
Select 'Programming --> Locking device'
Click 'Programme'
Wait until the programming process is complete
8.2 SmartHandle G2
LSM version 3.1 or higher and a Smart CD G2 programming device or newer
are required to use the SmartHandle.
Open the management and programming software (LSM) and select in
the database.
Select locking system (if several are available)
Select 'New lock'
Select 'SmartHandle G2' as lock type
Give the lock a name
You can select "Section" as an option
SmartHandle
(Manual)
8. Programming
95 / 136