C
Bolt sensor
D
Installation tool for bolt sensor
7.2.4.2 Step 1: Installing the fastening screw sensor
IMPORTANT
The fastening screw sensor may not be in locked final position during in-
stallation. The fastening screw sensor must be in the displayed "INSTALL-
ATION" position; otherwise ("LOCKED") the outer ring must be pushed
back carefully so that the spring mechanism is tensioned.
INSTALLATION
LOCKED
1. Insert the end of the fastening screw sensor cable (B) (with plug) into
the sensor screw drill hole.
2. Use a suitable tool (e.g. tweezers) to guide the plug out of the profile
cylinder opening on the inner side.
3. Insert fastening screw sensor into the sensor screw hole until it will go
no further.
9
A spring mechanism holds the fastening screw sensor in place in the
door lock.
7.2.4.3 Step 2: Bolt sensor installation
Preparing the bolt sensor
The bolt sensor (C) must be attached to the installation tool (D) as shown
in the following image in preparation for installation:
SmartHandle
(Manual)
7. Installation (manual)
39 / 136