4. Optional: In a lock with an 8.5 mm or 10 mm spindle, push the corres-
ponding sleeve (8 mm --> 8.5 mm [not included in the supply package]
or 8 mm --> 10 mm) through the retainer opening in the mortise lock
from the inside.
5. Push the inside fitting spindle through the retainer slot in the door's
mortise lock (6), so that the fitting is flush with the door. Ensure that
you do not squash the 3-pole cable when doing so.
6. Position the inside fitting (8) in such a way that it is parallel to the door.
7. Mark the drill holes required on the door through the corresponding
holes in the inside fitting (8).
8. Remove inside fitting (8) from the door.
9. Drill the 2 holes with a diameter of 8 mm through the door.
10. Push inlay (1) onto the outer handle (3). Depending on the handle
model, it may not be possible to fit it once the handle is installed.
11. Insert outer handle (3) horizontally into the outer fitting (4), placing it in
the direction that you require, depending on whether it is a DIN left-hand
or DIN right-hand door.
12. Place handle fastener piece (5) into position (see Figures 2 and 3).
13. Hold the outside handle (3) and use the spanner to rotate the fastener
piece (5) about 75° to the right until it fits into position (Figures 4 and
5). If you do not fit it correctly, the handle may come loose again.
14. The inside fitting (8) is mounted onto the inner surface of the door. Push
the inside fitting spindle through the retainer slot in the mortise lock (6)
and push the inside fitting (8) onto the door until it is about 1 cm away.
15. Push the inside fitting's 3-pole cable through the locking cylinder open-
ing in the mortise lock.
16. Push the inside fitting (8) until it is flush with the door.
17. The outer fitting (4) is mounted from the outer side of the door.
18. Insert the lower spacing bolt (7) into the outer fitting (4); the upper spa-
cing bolt (7) is pre-fastened into position in the factory.
19. Push the outer fitting retainer slot onto the spindle while pushing the
two spacing bolts (7) through the drill holes in the door at the same
time. In doing so, ensure that the cable from the inside fitting does not
get caught.
20.Connect the 3-pole cable from the inside fitting to the 3-pole cable
from the outer fitting. This cable can only be inserted in one direction.
Do not pull on the cables while doing so; just carefully secure the plug-in
connection into position.
21. The 2-pole cable from the outer fitting can hang freely, but must not get
caught when the outer cover (2) is fitted. Do not pull on the cable.
SmartHandle
(Manual)
7. Installation (manual)
46 / 136