OPENING
DIM A
TO 100°
4-23/32”
(120 mm)
100° - 120°
4-23/32”
(120 mm)
OVER 180° 5-5/32” (80 mm)
•
RIGHT HAND DOOR SHOWN
•
LEFT HAND DOOR OPPOSITE
•
DIMENSIONS ARE IN INCHES
•
DRAWING NOT TO SCALE
REGULAR ARM INSTALLATION (PULL SIDE) MOUNTING
6-1/2”(165mm)
1-9/16”(40mm)
1-1/4”(31.75mm)
1”(25.4mm)
3/4”
(19mm)
9-1/16”(230mm)
Hinge or Pivot
BOTTOM OF FRAME
704
_ZZZFDOUR\DOFRP_':*'&*$8*
500 SERIES INSTALLATION GUIDELINE:
INSTALLATION GUIDELINES:
1. Select degree of opening from table and use template dimension shown in above. Mark 4 holes on the
door for door closer and two (2) holes on the frame for arm shoe.
2. Drill pilot holes in door and frame for #14 all-purpose screws or drill and tap for 1/4; 20 machine screws.
3. Install adjustable forearm/arm shoe assembly to frame using screw provided.
4. Install main arm to top pinion shaft using screw provided.
5. Mount closer on door using screws provided, SPRING POWER ADJUSTING NUT MUST BE POSITIONED AWAY
FROM HINGE EDGE.
6. Adjust length of adjustable forearm so that adjustable forearm is perpendicular to frame when assembled
to preloaded main arm ( Illustration ). Secure forearm to main arm with screw provided.
7. Snap pinion cap over shaft at bottom of closer, (When using full cover, pinion cap is not necessary).
8. Adjust closing speed, back check control and spring power of door, following instruction as shown.
9. Shown Illustration above in regards for 704 drop plate use to accommodate the door closer body mounting
in some cases.