background image

 

 

 

1

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

INSTRUCTION MANUAL 

 

FOR SPOT WELDING  

 

MACHINES 

 

SPOT 7500 C 

 
 

 

 

JBDC 

 

 

Last update: 03.04.12 
 

Version : V1 

 

Summary of Contents for SPOT 7500 C

Page 1: ...1 INSTRUCTION MANUAL FOR SPOT WELDING MACHINES SPOT 7500 C JBDC Last update 03 04 12 Version V1...

Page 2: ...be cut off and off loaded 6 The electrodes arms and the other secondary conductors can reach a very high temperature and remain hot very long after having stopped the machine Be careful high risk of...

Page 3: ...Near the spot welding check there is neither no other power supply cable nor control lines nor phone cables nor radio or TV reception appliances nor watches nor mobile phones nor magnetic cards nor c...

Page 4: ...or delayed fuses 32A Case of dysfunction If the product releases the circuit breaker of the protection of installation please check that you have the right breaker size 32 A or more and D curve absolu...

Page 5: ...ow indicator of thermal protection Mode A Welding with the clamp in automatic mode The user shall enter the reference steel plate thickness Mode B Welding with the clamp in manual mode The user shall...

Page 6: ...A Welding with the clamp in automatic mode thickness to be selected Proposed parameters for welding 2 pieces of galvanised steel with the clamp Reference sheet thickness Intensity Time in p riods Puls...

Page 7: ...tar welding sliding hammer C 50 1 to 5 Gun Ring welding C 60 2 to 4 Gun Wavy wire dent pulling C 60 2 to 4 Gun Smoothing of bumps D 20 to 40 Gun Shrinking with carbon pen D 20 to 40 Pneumatics clamp W...

Page 8: ...wever all tools must stay clean in order to get the best performance of the unit When using the unit in pneumatic clamp mode check the good state of the CAPS electrodes flat rounded or bevelled If thi...

Page 9: ...ange 5 C 45 C Transport and storage Temperature range 25 C up to 70 C Hygrometry 80 Altitude 2000m Thermal protection by thermistor on the diode bridge 70 C MECHANICAL CHARACTERISTICS Protection degre...

Page 10: ...10 XV TROLLEY ASSEMBLY X30 X1 X26 X6 M8 x 12 M8 M8 x 85 M6...

Page 11: ...11...

Page 12: ...12...

Page 13: ...13...

Page 14: ...14 XVI Electrical schematics SPOT 7500 C...

Page 15: ...ct under water projections IP21 People wearing pace makers should not approach this product Risk of interference and disturbance of pace makers near of the product Caution Strong magnetic field People...