15 Disassembly
15.1 Snap-in on delivery
1. Disconnect the 3-pole cable from the inside fitting to the 3-pole cable
from the outer fitting. If necessary, also disconnect the LockNode cable
from the inside fitting.
2. Undo mounting screw (9) in the inside fitting (8) about 1 cm.
3. Use a soft object to knock on the mounting screw (9) to release the
tension in the snap-in mechanism (7).
4. Undo mounting screw (9) fully.
5. Hold the inside and outer fittings firmly while carefully pulling them
away from one another horizontally.
Fitted to the door:
IMPORTANT
General instructions: Depending on the handle model, it may not be pos-
sible to remove the inlay immediately. In such a case, push the inlay
through the opening in the cover and remove the cover. The inlay remains
on the handle and cannot be removed until the handle is dismounted.
Follow the same steps as for installation but in reverse order.
15.2 Storage mode for conventional fastening system
1. Disconnect the 3-pole cable from the inside fitting with the 3-pole cable
from the outer fitting. If necessary, also disconnect the LockNode cable
from the inside fitting.
2. Hold the inside and outer fittings firmly while pulling them away from
one another horizontally.
Fitted to the door:
IMPORTANT
General instructions: Depending on the handle model, it may not be pos-
sible to remove the inlay immediately. In such a case, push the inlay
through the opening in the cover and remove the cover. The inlay remains
on the handle and cannot be removed until the handle is dismounted.
Follow the same steps as for installation but in reverse order.
SmartHandle
(Manual)
15. Disassembly
124 / 136