Access event logging
SmartHandle logs up to 3,000 (G1) or up to 3,600 (G2) of the most recent
access events with the date, time and transponder ID (TID). The data can
be read via the network or using the programming device at any time.
Time zone control
SmartHandle can be programmed in such a way that authorised
transponders and smart cards/smart tags (G2) are only authorised for
access at specific times. There are 16,000 (G1) or 64,000 (G2) time zone
schedules available per locking system within the different time zone
schedules and 5+1 (G1) or 100+1 (G2) different time zone groups available
per locking device.
5.15.4 WP version
The WP version has been specially developed for the exterior shell of
buildings. This variant should always be used when the outer surface may
come into contact with damp. SmartHandle must not come into contact
with damp through the door or in indoor areas.
5.15.5 DP Version
Version with extra protection against levering open.
5.16 Network (WaveNet)
You can equip SmartHandle 3062 with a network node at any time. You do
not need to exchange any components to do so. Simply plug the network
node circuit board into its designated slot.
There is a special waterproof version of the network circuit board for use
outdoors. You require a WP network node for a WP SmartHandle. If you
use the WP version, you'll find the slot for the network node on the inner
side.
5.17 Network (DoorMonitoring)
The LockNodes are already permanently integrated into SmartHandles
with the DoorMonitoring function and cannot be replaced.