User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
–
Idle value
– the value which occurs at the idle state, which means before and after
generating the Profile/timer,
–
Section list
– submenu in which the user can define up to 100 sections generated
by the Profile/timer. For more information see
Chapter 7.12.1. Profile/timer -
–
Looping
– each Profile/timer has an ability to repeat its generated signal, this
parameter has options:
•
disabled
– the profile is not repeated,
•
counted
– allows to generate the profile specified number of times defined in
Loop count
parameter,
•
from logical channel
– allows to run the profile number of times equals the
value in the selected logical channel determined by the
Looping source
parameter,
•
infinite
– allows to infinite repeating of generated
Profile
,
–
Loop count
– this parameter is visible only if
Looping
parameter is set as
counted
,
defines the number of repetitions of generated Profile,
–
Looping source
– this parameter is visible only if
Looping
parameter is set as
from logical channel
. It allows to choose a logical channel from the list, which value
will be compared with the number of already made cycles of Profile,
–
Return to position
– this parameter is invisible if
Looping
parameter is set as
disabled
, allows to select a fixed position from which every next generated Profile
has to start,
Parameters in
Triggering times
submenu allows define moment of generating the
Profile with an accuracy of seconds. In every parameter the user can select any
number of options. If none option is selected in any parameter, after accepting, next
to that parameter “
Press to select
” description appears. Additionally, in that case,
the Profile will not be generated.
shown examples of Profile/timer: triggering times configuration
and output waveform. Operation of Profile in
'on time'
mode is similar to
edge (once)
mode -
see
Chapter 7.12.2. Profiles/timers - Triggering mode: level (gate), edge (once), edge
because after the rising edge of the triggering source the
Profile
will be generated in
whole, regardless of further changes of the signal source at time generating the Profile.
Fig. 7.104. Samples of time settings for
Profile/timer
181
Respectively:
0 sec, 20 sec,
30 sec, 50 sec
i