User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
Fig. 7.82. Two threshold control of the relay outputs
Fig. 7.83.
Levels
settings for
Mode
:
above
and
bellow level
(left) and
inside range
and
outside range
(right)
Timing
The parameters of this block include:
–
ON delay
- this parameter allows the setting of the time that must pass from the time
of exceeds
Level
value until the output switch from low to high state (see
–
OFF delay
- this parameter allows the user to set the time that must pass from the
time of exceeds
Level
value until the output switch from high to low state
–
Minimum ON time
- the minimum duration of a high state (if the output switches to
high state the low state will occur after this time) - see
–
Minimum OFF time
- the minimum duration of a low state (if the output switches to
low state the high state will occur after this time) - see
156
zone B
zone A
zone B
Lower level
Upper level
parameter
Hysteresis
parameter
Output
state