User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
detected, the Profile/timer will remain in pause state. Additionally, when in
Section list
parameter,
Shape
of
Section num. 1
is set as
const.value
, then
Profile/timer will set itself on
Final value
of this section, and when in
Section list
parameter,
Shape
of
Section num. 1
is set as
slope
, then
Profile/timer will set itself on its
Idle value
.
•
low level
– Profile/timer will be paused, when channel's value in
Pause source
parameter will be lower or equal zero ( ≤0 ) and will be resumed when this value
will be greater than zero ( >0 ). If Profile/timer is paused and new trigger will be
detected, the Profile/timer will remain in pause state. Additionally, when in
Section list
parameter,
Shape
of
Section num. 1
is set as
const.value
, then
Profile/timer will set itself on
Final value
of this section, and when in
Section list
parameter,
Shape
of
Section num. 1
is set as
slope
, then
Profile/timer will set itself on its
Idle value
.
•
rising edge
– Profile/timer will be paused, when the device detects channel's
value change from lower or equal zero ( ≤0 ) to greater than zero ( >0 ) in Pause
source parameter, and will be resumed when the device detects another change
like that in this channel. If Profile/timer is paused and new trigger will be
detected, the Profile/timer will react on this trigger like it would not be paused.
•
falling edge
– Profile/timer will be paused, when the device detects channel's
value change from greater than zero ( >0 ) to lower or equal zero ( ≤0 ) in
Pause
source
parameter, and will be resumed when the device detects another
change like that in this channel. If Profile/timer is paused and new trigger will be
detected, the Profile/timer will react on this trigger like it would not be paused.
–
Pause source
– this parameter is not visible when
Pause mode
parameter is set as
disabled
. It contains the list of Logical channels, where selected one will be pause
source for the Profile/timer,
–
Idle value
– the value before and after generating the defined the Profile,
–
Section list
– submenu where user can define Profile/timer consisting up to 100
sections. For more details see below in this
Chapter
.
–
Looping
– each Profile has a possibility to repeat its generated signal. This
parameter has following options:
•
disabled
– the Profile is generated only once,
•
counted
– allows to generate Profile specified number of times defined in
Loop count
parameter,
•
from logical channel
– this option allows the user to run a
Profile
a specified
number of times set in the selected logical channel defined by the
Looping source
parameter,
•
infinite
– this option allows the user to infinite repeating of generated
Profile
,
–
Loop count
– this parameter is visible only when
Looping
parameter is set on
counted
. It allows the user to enter number of generated Profile repetitions,
–
Looping source
– this parameter is visible only when
Looping
parameter is set on
from logical channe
l. It allows the user to select the logical channel from the list,
which value will be compared to the number of Profile cycle. If the cycle value is
equal or greater than value in the logical channel, next repetition of the Profile will
not start,
–
Return to position
– this parameter is invisible only when
Looping
parameter is set
as
disabled
. It allows user to select a section from the list, from which any next
generated Profile should starts. In case when
Section list
in empty, this parameter
is also empty,